GRACO INC. S10595
XP SYSTEM, 2:1, 115/58, COMPLETE, HAZ
GG 576206
XP SYSTEM, 2:1, 115/58, COMPLETE, HAZ
XP70 Cart System, Hazardous Location, 2:1 With Primary Heaters & Hose Heat, 240VTwo-component spraying made easy and affordable. The Graco XP70 Plural-Component Sprayer is designed to pump, mix and atomize high to 100% solid coatings with superior results. In addition, the XP70’s design allows you to gravity feed, which may eliminate the need for feed pumps, saving you money. When you upgrade from hand mixing, you'll find that the XP70 provides excellent return on investment, by reducing material waste and by using less clean-up solvent. Flexible options for mix ratio, pressure and flow rate – choose the right system for the application. If you occasionally change materials, the Graco XP Sprayers are the right choice. That’s because you can change the ratio by simply changing out one or two pump lowers. Available in 1:1, 1.5:1, 2:1, 2.5:1, 3:1 and 4:1 mix ratios.
High-pressure performance for two-part high-solids coatings. Reduced material waste No more throwing away unused mixed material at the end of the day Save money by using less clean-up solvent Consistent material quality - no more guesswork or human error in measuring materials Easy to operate - minimal training required Reduced maintenance costs Rated for 7250 psi (500 bar, 50 MPa) to handle viscous materials and long hose lengthsXP SYSTEM, 2:1, 115/58, CMPLT, NON-HAZ
GG 576207
XP SYSTEM, 2:1, 115/58, CMPLT, NON-HAZ
XP70 Cart System, Non-Hazardous, 2:1 With Primary Heaters & Hose Heat, 240VTwo-component spraying made easy and affordable. The Graco XP70 Plural-Component Sprayer is designed to pump, mix and atomize high to 100% solid coatings with superior results. In addition, the XP70’s design allows you to gravity feed, which may eliminate the need for feed pumps, saving you money. When you upgrade from hand mixing, you'll find that the XP70 provides excellent return on investment, by reducing material waste and by using less clean-up solvent. Flexible options for mix ratio, pressure and flow rate – choose the right system for the application. If you occasionally change materials, the Graco XP Sprayers are the right choice. That’s because you can change the ratio by simply changing out one or two pump lowers. Available in 1:1, 1.5:1, 2:1, 2.5:1, 3:1 and 4:1 mix ratios.
High-pressure performance for two-part high-solids coatings. Reduced material waste No more throwing away unused mixed material at the end of the day Save money by using less clean-up solvent Consistent material quality - no more guesswork or human error in measuring materials Easy to operate - minimal training required Reduced maintenance costs Rated for 7250 psi (500 bar, 50 MPa) to handle viscous materials and long hose lengthsXP SYSTEM, 3:1, 145/48, BF, CH, HS, JB
GG 576305
XP SYSTEM, 3:1, 145/48, BF, CH, HS, JB
XP70 Cart System, Non-Hazardous, 3:1 With Primary Heater, 240VTwo-component spraying made easy and affordable. The Graco XP70 Plural-Component Sprayer is designed to pump, mix and atomize high to 100% solid coatings with superior results. In addition, the XP70’s design allows you to gravity feed, which may eliminate the need for feed pumps, saving you money. When you upgrade from hand mixing, you'll find that the XP70 provides excellent return on investment, by reducing material waste and by using less clean-up solvent. Flexible options for mix ratio, pressure and flow rate – choose the right system for the application. If you occasionally change materials, the Graco XP Sprayers are the right choice. That’s because you can change the ratio by simply changing out one or two pump lowers. Available in 1:1, 1.5:1, 2:1, 2.5:1, 3:1 and 4:1 mix ratios.
High-pressure performance for two-part high-solids coatings. Reduced material waste No more throwing away unused mixed material at the end of the day Save money by using less clean-up solvent Consistent material quality - no more guesswork or human error in measuring materials Easy to operate - minimal training required Reduced maintenance costs Rated for 7250 psi (500 bar, 50 MPa) to handle viscous materials and long hose lengthsXP System, 3:1, 145/48, Complete, Haz
GG 576306
XP SYSTEM, 3:1, 145/48, COMPLETE, HAZ
Graco 576306 XP70 Skid System, Hazardous Location, 3:1 With Primary Heaters & Hose Heat, 240V
Two-component spraying made easy and affordable. The Graco XP70 Plural-Component Sprayer is designed to pump, mix and atomize high to 100% solid coatings with superior results. In addition, the XP70’s design allows you to gravity feed, which may eliminate the need for feed pumps, saving you money. When you upgrade from hand mixing, you'll find that the XP70 provides excellent return on investment, by reducing material waste and by using less clean-up solvent. Flexible options for mix ratio, pressure and flow rate – choose the right system for the application. If you occasionally change materials, the Graco XP Sprayers are the right choice. That’s because you can change the ratio by simply changing out one or two pump lowers. Available in 1:1, 1.5:1, 2:1, 2.5:1, 3:1 and 4:1 mix ratios.
Application: High-pressure performance for two-part high-solids coatings.- Reduced material waste
- No more throwing away unused mixed material at the end of the day
- Save money by using less clean-up solvent
- Easy to operate - minimal training required
- Reduced maintenance costs
- Rated for 7250 psi (500 bar, 50 MPa) to handle viscous materials and long hose lengths
- Series: XP70
- Air Inlet Size (in): 3/4
- Air Inlet Thread Gender: Female
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: With Primary Heaters & Hose Heat
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPSM
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: 7 Gallon Hoppers, XTR+ Gun, 35 ft integration Hose and Static Mixer, Merkur Flush Pump, Viscon HP Heaters, Hose Heat Circulation Kit, Remote Carriage, PressureTrak
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Air Consumption (SCFM): 75 scfm/gpm at 100 psi
- Maximum Air Inlet Pressure (bar): 12.07
- Maximum Air Inlet Pressure (kPa): 1207
- Maximum Air Inlet Pressure (MPa): 1.21
- Maximum Air Inlet Pressure (psi): 175
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 7570
- Maximum Flow Rate (GPM): 2
- Maximum Flow Rate (L/min): 7.57
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 469
- Maximum Working Pressure
XP SYSTEM, 3:1, 145/48, CMPLT, NON-HAZ
GG 576307
XP SYSTEM, 3:1, 145/48, CMPLT, NON-HAZ
XP70 Cart System, Non-Hazardous, 3:1 With Primary Heaters & Hose Heat, 240VTwo-component spraying made easy and affordable. The Graco XP70 Plural-Component Sprayer is designed to pump, mix and atomize high to 100% solid coatings with superior results. In addition, the XP70’s design allows you to gravity feed, which may eliminate the need for feed pumps, saving you money. When you upgrade from hand mixing, you'll find that the XP70 provides excellent return on investment, by reducing material waste and by using less clean-up solvent. Flexible options for mix ratio, pressure and flow rate – choose the right system for the application. If you occasionally change materials, the Graco XP Sprayers are the right choice. That’s because you can change the ratio by simply changing out one or two pump lowers. Available in 1:1, 1.5:1, 2:1, 2.5:1, 3:1 and 4:1 mix ratios.
High-pressure performance for two-part high-solids coatings. Reduced material waste No more throwing away unused mixed material at the end of the day Save money by using less clean-up solvent Consistent material quality - no more guesswork or human error in measuring materials Easy to operate - minimal training required Reduced maintenance costs Rated for 7250 psi (500 bar, 50 MPa) to handle viscous materials and long hose lengthsXP SYSTEM, 4:1, 145/36, BF, CH, HS, JB
GG 576405
XP SYSTEM, 4:1, 145/36, BF, CH, HS, JB
XP70 Cart System, Non-Hazardous, 4:1 With Primary Heater, 240VTwo-component spraying made easy and affordable. The Graco XP70 Plural-Component Sprayer is designed to pump, mix and atomize high to 100% solid coatings with superior results. In addition, the XP70’s design allows you to gravity feed, which may eliminate the need for feed pumps, saving you money. When you upgrade from hand mixing, you'll find that the XP70 provides excellent return on investment, by reducing material waste and by using less clean-up solvent. Flexible options for mix ratio, pressure and flow rate – choose the right system for the application. If you occasionally change materials, the Graco XP Sprayers are the right choice. That’s because you can change the ratio by simply changing out one or two pump lowers. Available in 1:1, 1.5:1, 2:1, 2.5:1, 3:1 and 4:1 mix ratios.
High-pressure performance for two-part high-solids coatings. Reduced material waste No more throwing away unused mixed material at the end of the day Save money by using less clean-up solvent Consistent material quality - no more guesswork or human error in measuring materials Easy to operate - minimal training required Reduced maintenance costs Rated for 7250 psi (500 bar, 50 MPa) to handle viscous materials and long hose lengthsXP System, 4:1, 145/36, Complete, Haz
GG 576406
XP SYSTEM, 4:1, 145/36, COMPLETE, HAZ
Graco 576406 XP70 Skid System, Hazardous Location, 4:1 With Primary Heaters & Hose Heat, 240V
Two-component spraying made easy and affordable. The Graco XP70 Plural-Component Sprayer is designed to pump, mix and atomize high to 100% solid coatings with superior results. In addition, the XP70’s design allows you to gravity feed, which may eliminate the need for feed pumps, saving you money. When you upgrade from hand mixing, you'll find that the XP70 provides excellent return on investment, by reducing material waste and by using less clean-up solvent. Flexible options for mix ratio, pressure and flow rate – choose the right system for the application. If you occasionally change materials, the Graco XP Sprayers are the right choice. That’s because you can change the ratio by simply changing out one or two pump lowers. Available in 1:1, 1.5:1, 2:1, 2.5:1, 3:1 and 4:1 mix ratios.
Application: High-pressure performance for two-part high-solids coatings.- Reduced material waste
- No more throwing away unused mixed material at the end of the day
- Save money by using less clean-up solvent
- Easy to operate - minimal training required
- Reduced maintenance costs
- Rated for 7250 psi (500 bar, 50 MPa) to handle viscous materials and long hose lengths
- Series: XP70
- Air Inlet Size (in): 3/4
- Air Inlet Thread Gender: Female
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: With Primary Heaters & Hose Heat
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPSM
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: 7 Gallon Hoppers, XTR+ Gun, 35 ft integration Hose and Static Mixer, Merkur Flush Pump, Viscon HP Heaters, Hose Heat Circulation Kit, Remote Carriage, PressureTrak
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Air Consumption (SCFM): 75 scfm/gpm at 100 psi
- Maximum Air Inlet Pressure (bar): 12.07
- Maximum Air Inlet Pressure (kPa): 1207
- Maximum Air Inlet Pressure (MPa): 1.21
- Maximum Air Inlet Pressure (psi): 175
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 7200
- Maximum Flow Rate (GPM): 1.9
- Maximum Flow Rate (L/min): 7.2
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
- Maximum Working Pressur
XP System, 4:1, 145/36, Cmplt, Non-Haz
GG 576407
XP SYSTEM, 4:1, 145/36, CMPLT, NON-HAZ
Graco 576407 XP70 Skid System, Non-Hazardous, 4:1 With Primary Heaters & Hose Heat, 240V
Two-component spraying made easy and affordable. The Graco XP70 Plural-Component Sprayer is designed to pump, mix and atomize high to 100% solid coatings with superior results. In addition, the XP70’s design allows you to gravity feed, which may eliminate the need for feed pumps, saving you money. When you upgrade from hand mixing, you'll find that the XP70 provides excellent return on investment, by reducing material waste and by using less clean-up solvent. Flexible options for mix ratio, pressure and flow rate – choose the right system for the application. If you occasionally change materials, the Graco XP Sprayers are the right choice. That’s because you can change the ratio by simply changing out one or two pump lowers. Available in 1:1, 1.5:1, 2:1, 2.5:1, 3:1 and 4:1 mix ratios.
Application: High-pressure performance for two-part high-solids coatings.- Reduced material waste
- No more throwing away unused mixed material at the end of the day
- Save money by using less clean-up solvent
- Easy to operate - minimal training required
- Reduced maintenance costs
- Rated for 7250 psi (500 bar, 50 MPa) to handle viscous materials and long hose lengths
- Series: XP70
- Air Inlet Size (in): 3/4
- Air Inlet Thread Gender: Female
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: With Primary Heaters & Hose Heat
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPSM
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: 7 Gallon Hoppers, Merkur Solvent Flush Pump, XTR+ Gun, 35 ft integration Hose and Static Mixer, 240V Junction Box, Viscon HP Heaters, Hose Heat Circulation Kit, Remote Carriage, PressureTrak
- Location Category: Non-Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Air Consumption (SCFM): 75 scfm/gpm at 100 psi
- Maximum Air Inlet Pressure (bar): 12.07
- Maximum Air Inlet Pressure (kPa): 1207
- Maximum Air Inlet Pressure (MPa): 1.21
- Maximum Air Inlet Pressure (psi): 175
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 7200
- Maximum Flow Rate (GPM): 1.9
- Maximum Flow Rate (L/min): 7.2
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
XP SYSTEM, XP70S, 1:1, 145/145, 240, WJ
GG 577101
XP SYSTEM, XP70S, 1:1, 145/145, 240, WJ
XP70s-hf Skid System, Non-Hazardous, 1:1 With Water Jacketed Hose, 240V The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 25 gallon heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use 25 gallon Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP SYSTEM, XP70S, 1:1, 145/145, 240, EH
GG 577103
XP SYSTEM, XP70S, 1:1, 145/145, 240, EH
XP70s-hf Skid System, Non-Hazardous, 1:1 With Electric Heated Hose, 240V The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 25 gallon heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use 25 gallon Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP System, XP70S, 1:1, 145/145, 240H, Wj
GG 577111
XP SYSTEM, XP70S, 1:1, 145/145, 240H, WJ
Graco 577111 XP70s-hf Skid System, Hazardous Location, 1:1 With Water Jacketed Hose, 240V
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Water Jacketed Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: Merkur Solvent Flush Pump, Remote Manifold Carriage, XTR5+ Gun, 35 ft Integration Hose and Static Mixer, Heated Hose Controller, Ratio Check Kit
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 11600
- Maximum Flow Rate (GPM): 3
- Maximum Flow Rate (L/min): 11.3
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 490
- Maximum Spray Pressure (kPa): 49000
- Maximum Spray Pressure (MPa): 49
- Maximum Spray Pressure (psi): 7100
- Maximum Working Pressure (bar): 490
- Maximum Working Pressure (kPa): 49000
- Maximum Working Pressure (MPa): 49
- Maximum Working Pressure (psi): 7100
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 1:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 1:1, 145/145, 240H, Eh
GG 577113
XP SYSTEM, XP70S, 1:1, 145/145, 240H, EH
Graco 577113 XP70s-hf Skid System, Hazardous Location, 1:1 With Electric Heated Hose, 240V
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: Merkur Solvent Flush Pump, Remote Manifold Carriage, XTR5+ Gun, 35 ft Integration Hose and Static Mixer, Electric Heated Hose Controller, Ratio Check Kit
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 11600
- Maximum Flow Rate (GPM): 3
- Maximum Flow Rate (L/min): 11.3
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 490
- Maximum Spray Pressure (kPa): 49000
- Maximum Spray Pressure (MPa): 49
- Maximum Spray Pressure (psi): 7100
- Maximum Working Pressure (bar): 490
- Maximum Working Pressure (kPa): 49000
- Maximum Working Pressure (MPa): 49
- Maximum Working Pressure (psi): 7100
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 1:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 1:1, 145/145, 480, Wj
GG 577121
XP SYSTEM, XP70S, 1:1, 145/145, 480, WJ
Graco 577121 XP70 High Flow Skid, 1:1 Mix Ratio, 480V, Viscon HF Heaters, Junction Box, Water Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Water Jacketed Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Non-Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 11600
- Maximum Flow Rate (GPM): 3
- Maximum Flow Rate (L/min): 11.3
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 490
- Maximum Spray Pressure (kPa): 49000
- Maximum Spray Pressure (MPa): 49
- Maximum Spray Pressure (psi): 7100
- Maximum Working Pressure (bar): 490
- Maximum Working Pressure (kPa): 49000
- Maximum Working Pressure (MPa): 49
- Maximum Working Pressure (psi): 7100
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 1:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 1:1, 145/145, 480, Eh
GG 577123
XP SYSTEM, XP70S, 1:1, 145/145, 480, EH
Graco 577123 XP70 High Flow Skid, 1:1 Mix Ratio, 480V, Viscon HF Heaters, Junction Box, Electric Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Non-Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 11600
- Maximum Flow Rate (GPM): 3
- Maximum Flow Rate (L/min): 11.3
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 490
- Maximum Spray Pressure (kPa): 49000
- Maximum Spray Pressure (MPa): 49
- Maximum Spray Pressure (psi): 7100
- Maximum Working Pressure (bar): 490
- Maximum Working Pressure (kPa): 49000
- Maximum Working Pressure (MPa): 49
- Maximum Working Pressure (psi): 7100
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 1:1
- Power Source: Air
- Product Type: Plural Component
XP SYSTEM, XP70S, 1:1, 145/145, 480H, WJ
GG 577131
XP SYSTEM, XP70S, 1:1, 145/145, 480H, WJ
XP70 High Flow Skid, 1:1 Mix Ratio, 480V, Hazardous Viscon HF Heaters, Hazardous Junction Box, Water Heated Hose Control The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use, Designed for Hazardous Location approval 94 litres Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP System, XP70S, 1:1, 145/145, 480H, Eh
GG 577133
XP SYSTEM, XP70S, 1:1, 145/145, 480H, EH
Graco 577133 XP70 High Flow Skid, 1:1 Mix Ratio, 480V, Hazardous Viscon HF Heaters, Hazardous Junction Box, Electric Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 25 gallon heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 25 gallon Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 11600
- Maximum Flow Rate (GPM): 3
- Maximum Flow Rate (L/min): 11.3
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 490
- Maximum Spray Pressure (kPa): 49000
- Maximum Spray Pressure (MPa): 49
- Maximum Spray Pressure (psi): 7100
- Maximum Working Pressure (bar): 490
- Maximum Working Pressure (kPa): 49000
- Maximum Working Pressure (MPa): 49
- Maximum Working Pressure (psi): 7100
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 1:1
- Power Source: Air
- Product Type: Plural Component
XP SYSTEM, XP70S, 2:1, 180/90, 240, WJ
GG 577201
XP SYSTEM, XP70S, 2:1, 180/90, 240, WJ
XP70s-hf Skid System, Non-Hazardous, 2:1 With Water Jacketed Hose, 240V The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 25 gallon heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use 25 gallon Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP SYSTEM, XP70S, 2:1, 180/90, 240, EH
GG 577203
XP SYSTEM, XP70S, 2:1, 180/90, 240, EH
XP70s-hf Skid System, Non-Hazardous, 2:1 With Electric Heated Hose, 240V The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use 94 litres Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP System, XP70S, 2:1, 180/90, 240H, Wj
GG 577211
XP SYSTEM, XP70S, 2:1, 180/90, 240H, WJ
Graco 577211 XP70s-hf Skid System, Hazardous Location, 2:1 With Water Jacketed Hose, 240V
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Water Jacketed Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: Merkur Solvent Flush Pump, Remote Manifold Carriage, XTR5+ Gun, 35 ft Integration Hose and Static Mixer, Heated Hose Controller, Ratio Check Kit
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 10800
- Maximum Flow Rate (GPM): 2.8
- Maximum Flow Rate (L/min): 10.6
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
- Maximum Working Pressure (kPa): 50000
- Maximum Working Pressure (MPa): 50
- Maximum Working Pressure (psi): 7250
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 2:1
- Power Source: Air
- Product Type: Plural Component
XP SYSTEM, XP70S, 2:1, 180/90, 480, WJ
GG 577221
XP SYSTEM, XP70S, 2:1, 180/90, 480, WJ
XP70 High Flow Skid, 2:1 Mix Ratio, 480V, Viscon HF Heaters, Junction Box, Water Heated Hose Control The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use 94 litres Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP System, XP70S, 2:1, 180/90, 240H, Eh
GG 577213
XP SYSTEM, XP70S, 2:1, 180/90, 240H, EH
Graco 577213 XP70s-hf Skid System, Hazardous Location, 2:1 With Electric Heated Hose, 240V
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: Merkur Solvent Flush Pump, Remote Manifold Carriage, XTR5+ Gun, 35 ft Integration Hose and Static Mixer, Electric Heated Hose Controller, Ratio Check Kit
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 10800
- Maximum Flow Rate (GPM): 2.8
- Maximum Flow Rate (L/min): 10.6
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
- Maximum Working Pressure (kPa): 50000
- Maximum Working Pressure (MPa): 50
- Maximum Working Pressure (psi): 7250
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 2:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 2:1, 180/90, 480, Eh
GG 577223
XP SYSTEM, XP70S, 2:1, 180/90, 480, EH
Graco 577223 XP70 High Flow Skid, 2:1 Mix Ratio, 480V, Viscon HF Heaters, Junction Box, Electric Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Non-Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 10800
- Maximum Flow Rate (GPM): 2.8
- Maximum Flow Rate (L/min): 10.6
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
- Maximum Working Pressure (kPa): 50000
- Maximum Working Pressure (MPa): 50
- Maximum Working Pressure (psi): 7250
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 2:1
- Power Source: Air
- Product Type: Plural Component
XP SYSTEM, XP70S, 2:1, 180/90, 480H, WJ
GG 577231
XP SYSTEM, XP70S, 2:1, 180/90, 480H, WJ
XP70 High Flow Skid, 2:1 Mix Ratio, 480V, Hazardous Viscon HF Heaters, Hazardous Junction Box, Water Heated Hose Control The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use, Designed for Hazardous Location approval 94 litres Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP System, XP70S, 2:1, 180/90, 480H, Eh
GG 577233
XP SYSTEM, XP70S, 2:1, 180/90, 480H, EH
Graco 577233 XP70 High Flow Skid, 2:1 Mix Ratio, 480V, Hazardous Viscon HF Heaters, Hazardous Junction Box, Electric Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 10800
- Maximum Flow Rate (GPM): 2.8
- Maximum Flow Rate (L/min): 10.6
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
- Maximum Working Pressure (kPa): 50000
- Maximum Working Pressure (MPa): 50
- Maximum Working Pressure (psi): 7250
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 2:1
- Power Source: Air
- Product Type: Plural Component
XP SYSTEM, XP70S, 3:1, 220/72, 240, WJ
GG 577301
XP SYSTEM, XP70S, 3:1, 220/72, 240, WJ
XP70s-hf Skid System, Non-Hazardous, 3:1 With Water Jacketed Hose, 240V The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 25 gallon heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use 25 gallon Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP System, XP70S, 3:1, 220/72, 240H, Wj
GG 577311
XP SYSTEM, XP70S, 3:1, 220/72, 240H, WJ
Graco 577311 XP70s-hf Skid System, Hazardous Location, 3:1 With Water Jacketed Hose, 240V
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Water Jacketed Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: Merkur Solvent Flush Pump, Remote Manifold Carriage, XTR5+ Gun, 35 ft Integration Hose and Static Mixer, Heated Hose Controller, Ratio Check Kit
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 11680
- Maximum Flow Rate (GPM): 3
- Maximum Flow Rate (L/min): 11.3
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 490
- Maximum Spray Pressure (kPa): 49000
- Maximum Spray Pressure (MPa): 49
- Maximum Spray Pressure (psi): 7100
- Maximum Working Pressure (bar): 490
- Maximum Working Pressure (kPa): 49000
- Maximum Working Pressure (MPa): 49
- Maximum Working Pressure (psi): 7100
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 3:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 3:1, 220/72, 240H, Eh
GG 577313
XP SYSTEM, XP70S, 3:1, 220/72, 240H, EH
Graco 577313 XP70s-hf Skid System, Hazardous Location, 3:1 With Electric Heated Hose, 240V
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: Merkur Solvent Flush Pump, Remote Manifold Carriage, XTR5+ Gun, 35 ft Integration Hose and Static Mixer, Electric Heated Hose Controller, Ratio Check Kit
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 11680
- Maximum Flow Rate (GPM): 3
- Maximum Flow Rate (L/min): 11.3
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 490
- Maximum Spray Pressure (kPa): 49000
- Maximum Spray Pressure (MPa): 49
- Maximum Spray Pressure (psi): 7100
- Maximum Working Pressure (bar): 490
- Maximum Working Pressure (kPa): 49000
- Maximum Working Pressure (MPa): 49
- Maximum Working Pressure (psi): 7100
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 3:1
- Power Source: Air
- Product Type: Plural Component
XP SYSTEM, XP70S, 3:1, 220/72, 240, EH
GG 577303
XP SYSTEM, XP70S, 3:1, 220/72, 240, EH
XP70s-hf Skid System, Non-Hazardous, 3:1 With Electric Heated Hose, 240V The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use 94 litres Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP System, XP70S, 3:1, 220/72, 480, Wj
GG 577321
XP SYSTEM, XP70S, 3:1, 220/72, 480, WJ
Graco 577321 XP70 High Flow Skid, 3:1 Mix Ratio, 480V, Viscon HF Heaters, Junction Box, Water Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Water Jacketed Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Non-Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 11680
- Maximum Flow Rate (GPM): 3
- Maximum Flow Rate (L/min): 11.3
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 490
- Maximum Spray Pressure (kPa): 49000
- Maximum Spray Pressure (MPa): 49
- Maximum Spray Pressure (psi): 7100
- Maximum Working Pressure (bar): 490
- Maximum Working Pressure (kPa): 49000
- Maximum Working Pressure (MPa): 49
- Maximum Working Pressure (psi): 7100
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 3:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 3:1, 220/72, 480, Eh
GG 577323
XP SYSTEM, XP70S, 3:1, 220/72, 480, EH
Graco 577323 XP70 High Flow Skid, 3:1 Mix Ratio, 480V, Viscon HF Heaters, Junction Box, Electric Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Non-Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 11680
- Maximum Flow Rate (GPM): 3
- Maximum Flow Rate (L/min): 11.3
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 490
- Maximum Spray Pressure (kPa): 49000
- Maximum Spray Pressure (MPa): 49
- Maximum Spray Pressure (psi): 7100
- Maximum Working Pressure (bar): 490
- Maximum Working Pressure (kPa): 49000
- Maximum Working Pressure (MPa): 49
- Maximum Working Pressure (psi): 7100
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 3:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 3:1, 220/72, 480H, Wj
GG 577331
XP SYSTEM, XP70S, 3:1, 220/72, 480H, WJ
Graco 577331 XP70 High Flow Skid, 3:1 Mix Ratio, 480V, Hazardous Viscon HF Heaters, Hazardous Junction Box, Water Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Water Jacketed Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 11680
- Maximum Flow Rate (GPM): 3
- Maximum Flow Rate (L/min): 11.3
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 490
- Maximum Spray Pressure (kPa): 49000
- Maximum Spray Pressure (MPa): 49
- Maximum Spray Pressure (psi): 7100
- Maximum Working Pressure (bar): 490
- Maximum Working Pressure (kPa): 49000
- Maximum Working Pressure (MPa): 49
- Maximum Working Pressure (psi): 7100
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 3:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 3:1, 220/72, 480H, Eh
GG 577333
XP SYSTEM, XP70S, 3:1, 220/72, 480H, EH
Graco 577333 XP70 High Flow Skid, 3:1 Mix Ratio, 480V, Hazardous Viscon HF Heaters, Hazardous Junction Box, Electric Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 11680
- Maximum Flow Rate (GPM): 3
- Maximum Flow Rate (L/min): 11.3
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 490
- Maximum Spray Pressure (kPa): 49000
- Maximum Spray Pressure (MPa): 49
- Maximum Spray Pressure (psi): 7100
- Maximum Working Pressure (bar): 490
- Maximum Working Pressure (kPa): 49000
- Maximum Working Pressure (MPa): 49
- Maximum Working Pressure (psi): 7100
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 3:1
- Power Source: Air
- Product Type: Plural Component
XP SYSTEM, XP70S, 4:1, 220/54, 240, WJ
GG 577401
XP SYSTEM, XP70S, 4:1, 220/54, 240, WJ
XP70s-hf Skid System, Non-Hazardous, 4:1 With Water Jacketed Hose, 240V The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 25 gallon heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use 25 gallon Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP SYSTEM, XP70S, 4:1, 220/54, 240, EH
GG 577403
XP SYSTEM, XP70S, 4:1, 220/54, 240, EH
XP70s-hf Skid System, Non-Hazardous, 4:1 With Electric Heated Hose, 240V The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use 94 litres Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP System, XP70S, 4:1, 220/54, 240H, Wj
GG 577411
XP SYSTEM, XP70S, 4:1, 220/54, 240H, WJ
Graco 577411 XP70s-hf Skid System, Hazardous Location, 4:1 With Water Jacketed Hose, 240V
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Water Jacketed Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: Merkur Solvent Flush Pump, Remote Manifold Carriage, XTR5+ Gun, 35 ft Integration Hose and Static Mixer, Heated Hose Controller, Ratio Check Kit
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 10960
- Maximum Flow Rate (GPM): 2.8
- Maximum Flow Rate (L/min): 10.6
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
- Maximum Working Pressure (kPa): 50000
- Maximum Working Pressure (MPa): 50
- Maximum Working Pressure (psi): 7250
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 4:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 4:1, 220/54, 480, Eh
GG 577423
XP SYSTEM, XP70S, 4:1, 220/54, 480, EH
Graco 577423 XP70 High Flow Skid, 4:1 Mix Ratio, 480V, Viscon HF Heaters, Junction Box, Electric Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Non-Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 10960
- Maximum Flow Rate (GPM): 2.8
- Maximum Flow Rate (L/min): 10.6
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
- Maximum Working Pressure (kPa): 50000
- Maximum Working Pressure (MPa): 50
- Maximum Working Pressure (psi): 7250
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 4:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 4:1, 220/54, 480, Wj
GG 577421
XP SYSTEM, XP70S, 4:1, 220/54, 480, WJ
Graco 577421 XP70 High Flow Skid, 4:1 Mix Ratio, 480V, Viscon HF Heaters, Junction Box, Water Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Water Jacketed Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Non-Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 10960
- Maximum Flow Rate (GPM): 2.8
- Maximum Flow Rate (L/min): 10.6
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
- Maximum Working Pressure (kPa): 50000
- Maximum Working Pressure (MPa): 50
- Maximum Working Pressure (psi): 7250
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 4:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 4:1, 220/54, 240H, Eh
GG 577413
XP SYSTEM, XP70S, 4:1, 220/54, 240H, EH
Graco 577413 XP70s-hf Skid System, Hazardous Location, 4:1 With Electric Heated Hose, 240V
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: Merkur Solvent Flush Pump, Remote Manifold Carriage, XTR5+ Gun, 35 ft Integration Hose and Static Mixer, Electric Heated Hose Controller, Ratio Check Kit
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 10960
- Maximum Flow Rate (GPM): 2.8
- Maximum Flow Rate (L/min): 10.6
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
- Maximum Working Pressure (kPa): 50000
- Maximum Working Pressure (MPa): 50
- Maximum Working Pressure (psi): 7250
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 4:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 4:1, 220/54, 480H, Wj
GG 577431
XP SYSTEM, XP70S, 4:1, 220/54, 480H, WJ
Graco 577431 XP70 High Flow Skid, 4:1 Mix Ratio, 480V, Hazardous Viscon HF Heaters, Hazardous Junction Box, Water Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Water Jacketed Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 10960
- Maximum Flow Rate (GPM): 2.8
- Maximum Flow Rate (L/min): 10.6
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
- Maximum Working Pressure (kPa): 50000
- Maximum Working Pressure (MPa): 50
- Maximum Working Pressure (psi): 7250
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 4:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP70S, 4:1, 220/54, 480H, Eh
GG 577433
XP SYSTEM, XP70S, 4:1, 220/54, 480H, EH
Graco 577433 XP70 High Flow Skid, 4:1 Mix Ratio, 480V, Hazardous Viscon HF Heaters, Hazardous Junction Box, Electric Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP70s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Skid Mount with 25 gal Heated & Agitated Hoppers
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 10960
- Maximum Flow Rate (GPM): 2.8
- Maximum Flow Rate (L/min): 10.6
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 500
- Maximum Spray Pressure (kPa): 50000
- Maximum Spray Pressure (MPa): 50
- Maximum Spray Pressure (psi): 7250
- Maximum Working Pressure (bar): 500
- Maximum Working Pressure (kPa): 50000
- Maximum Working Pressure (MPa): 50
- Maximum Working Pressure (psi): 7250
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 4:1
- Power Source: Air
- Product Type: Plural Component
XP SYSTEM, XP50S, 1:1, 220/220, 240, WJ
GG 578101
XP SYSTEM, XP50S, 1:1, 220/220, 240, WJ
XP50s-hf Skid System, Non-Hazardous, 1:1 With Water Jacketed Hose, 240V The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 25 gallon heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use 25 gallon Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedXP System, XP50S, 1:1, 220/220, 240, Eh
GG 578103
XP SYSTEM, XP50S, 1:1, 220/220, 240, EH
Graco 578103 XP50s-hf Skid System, Non-Hazardous, 1:1 With Electric Heated Hose, 240V
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP50s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: Merkur Solvent Flush Pump, Remote Manifold Carriage, XTR5+ Gun, 35 ft Integration Hose and Static Mixer, Electric Heated Hose Controller, Ratio Check Kit
- Location Category: Non-Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 17600
- Maximum Flow Rate (GPM): 4.6
- Maximum Flow Rate (L/min): 17.4
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 330
- Maximum Spray Pressure (kPa): 33000
- Maximum Spray Pressure (MPa): 33
- Maximum Spray Pressure (psi): 4750
- Maximum Working Pressure (bar): 330
- Maximum Working Pressure (kPa): 33000
- Maximum Working Pressure (MPa): 33
- Maximum Working Pressure (psi): 4750
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 1:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP50S, 1:1, 220/220, 240H, Wj
GG 578111
XP SYSTEM, XP50S, 1:1, 220/220, 240H, WJ
Graco 578111 XP50s-hf Skid System, Hazardous Location, 1:1 With Water Jacketed Hose, 240V
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP50s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Water Jacketed Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: Merkur Solvent Flush Pump, Remote Manifold Carriage, XTR5+ Gun, 35 ft Integration Hose and Static Mixer, Heated Hose Controller, Ratio Check Kit
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 17600
- Maximum Flow Rate (GPM): 4.6
- Maximum Flow Rate (L/min): 17.4
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 330
- Maximum Spray Pressure (kPa): 33000
- Maximum Spray Pressure (MPa): 33
- Maximum Spray Pressure (psi): 4750
- Maximum Working Pressure (bar): 330
- Maximum Working Pressure (kPa): 33000
- Maximum Working Pressure (MPa): 33
- Maximum Working Pressure (psi): 4750
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 1:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP50S, 1:1, 220/220, 240H, Eh
GG 578113
XP SYSTEM, XP50S, 1:1, 220/220, 240H, EH
Graco 578113 XP50s-hf Skid System, Hazardous Location, 1:1 With Electric Heated Hose, 240V
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 25 gallon heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use, Designed for Hazardous Location approval
- 25 gallon Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP50s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Electric Heated Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Includes: Merkur Solvent Flush Pump, Remote Manifold Carriage, XTR5+ Gun, 35 ft Integration Hose and Static Mixer, Electric Heated Hose Controller, Ratio Check Kit
- Location Category: Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 17600
- Maximum Flow Rate (GPM): 4.6
- Maximum Flow Rate (L/min): 17.4
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 330
- Maximum Spray Pressure (kPa): 33000
- Maximum Spray Pressure (MPa): 33
- Maximum Spray Pressure (psi): 4750
- Maximum Working Pressure (bar): 330
- Maximum Working Pressure (kPa): 33000
- Maximum Working Pressure (MPa): 33
- Maximum Working Pressure (psi): 4750
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 1:1
- Power Source: Air
- Product Type: Plural Component
XP System, XP50S, 1:1, 220/220, 480, Wj
GG 578121
XP SYSTEM, XP50S, 1:1, 220/220, 480, WJ
Graco 578121 XP50 High Flow Skid, 1:1 Mix Ratio, 480V, Viscon HF Heaters, Junction Box, Water Heated Hose Control
The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 94 litres heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive.
- Approved for Ordinary Location use
- 94 litres Stainless Steel lined hoppers with heater and agitator
- Solvent flush pump included
- Series: XP50s-hf
- Air Inlet Size (in): 1
- Air Inlet Thread Gender: Male
- Air Inlet Thread Type: NPSM
- Applicator Type: Automatic Airless, Manual Airless
- Compatible Material: Protective Coating, Primer, Epoxy, Polyurethane, Two-Component Coating, Solvents
- Component Type: Plural-Component
- Configuration: Water Jacketed Hose
- Fluid Inlet Size (in): 1-1/4
- Fluid Inlet Thread Gender: Male
- Fluid Inlet Thread Type: NPT
- Fluid Outlet Size (in): 1/2
- Fluid Outlet Thread Gender: Female
- Fluid Outlet Thread Type: NPT
- Flush Type: Solvent
- Hose Length (ft): 35
- Hose Length (m): 10.7
- Location Category: Non-Hazardous Location
- Material Application: Coatings, Paints, Primers
- Maximum Cycle Rate (CPM): 40
- Maximum Flow Rate (cc/min): 17600
- Maximum Flow Rate (GPM): 4.6
- Maximum Flow Rate (L/min): 17.4
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Fluid Temperature (°C): 71
- Maximum Fluid Temperature (°F): 160
- Maximum Fluid Viscosity (cP): 20000
- Maximum Hose Length (ft): 300
- Maximum Hose Length (m): 91.4
- Maximum Operating Temperature (°C): 54
- Maximum Operating Temperature (°F): 130
- Maximum Spray Pressure (bar): 330
- Maximum Spray Pressure (kPa): 33000
- Maximum Spray Pressure (MPa): 33
- Maximum Spray Pressure (psi): 4750
- Maximum Working Pressure (bar): 330
- Maximum Working Pressure (kPa): 33000
- Maximum Working Pressure (MPa): 33
- Maximum Working Pressure (psi): 4750
- Measuring Type: Fixed Mechanical Positive Displacement
- Minimum Fluid Viscosity (cP): 200
- Mix Ratio: 1:1
- Power Source: Air
- Product Type: Plural Component
XP SYSTEM, XP50S, 1:1, 220/220, 480, EH
GG 578123
XP SYSTEM, XP50S, 1:1, 220/220, 480, EH
XP50 High Flow Skid, 1:1 Mix Ratio, 480V, Viscon HF Heaters, Junction Box, Electric Heated Hose Control The XP high flow skid systems combine the XP Sprayers with the powerful XL 10000 air motor. The XPs-hf systems provide greater performance, allowing the flexibility of multi-gun application to shorten your project completion time. With the durable, 25 gallon heated and agitated tanks, your coatings will obtain the best conditioning to meet the highest demand applications – making you more productive. Approved for Ordinary Location use 25 gallon Stainless Steel lined hoppers with heater and agitator Solvent flush pump includedMHH VALVE, ASSY 30T
GG 562690
MHH VALVE, ASSY 30T
Manzel® MHH Modular Divider Valve .030 TwinSame capable design as the Trabon MSP Series, with even tighter and more exacting tolerances.
The Manzel MHH Series delivers highly accurate lube delivery for demanding high pressure grease and oil applications. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-000-645MSP VALVE, ASSY IND MSP 25S
GG 562730
MSP VALVE, ASSY IND MSP 25S
Trabon® MSP Modular Divider Valve with Right Cycle Pin - MSP-25S - 0.050 in³ (0.82 cm³)The Trabon MSP Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best!
Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-100-745MSP VALVE, ASSY IND MSP 35S
GG 562732
MSP VALVE, ASSY IND MSP 35S
Trabon® MSP Modular Divider Valve with Right Cycle Pin - MSP-35S - 0.070 in³ (1.15 cm³)The Trabon MSP Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best!
Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-100-765MSP VALVE, ASSY IND MSP 40S
GG 562733
MSP VALVE, ASSY IND MSP 40S
Trabon® MSP Modular Divider Valve with Right Cycle Pin - MSP-40S - 0.080 in³ (1.31 cm³)The Trabon MSP Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best!
Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-100-775MSP VALVE, ASSY IND MSP 30T
GG 562741
MSP VALVE, ASSY IND MSP 30T
Trabon® MSP Modular Divider Valve with Right Cycle Pin - MSP-30T - 0.030 in³ (0.49 cm³)The Trabon MSP Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best!
Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-100-955MSP VALVE, ASSY IND MSP 25T
GG 562740
MSP VALVE, ASSY IND MSP 25T
Trabon® MSP Modular Divider Valve with Right Cycle Pin - MSP-25T - 0.025 in³ (0.41 cm³)The Trabon MSP Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best!
Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-100-945MSP VALVE, ASSY IND RIGHT MSP 35T
GG 562742
MSP VALVE, ASSY IND RIGHT MSP 35T
Trabon® MSP Modular Divider Valve with Right Cycle Pin - MSP-35T - 0.035 in³ (0.57 cm³)The Trabon MSP Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best!
Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-100-965MSP VALVE, ASSY MSP-10S-SS
GG 562755
MSP VALVE, ASSY MSP-10S-SS
Trabon® MSP Stainless Steel Modular Divider Valve - MSP-10S-SS - 0.020 in³ (0.33 cm³) The Trabon MSP Stainless Steel Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best! You get more durability with the same high-quality performance and precision machining as the carbon steel version. The stainless steel MSP valves and accessories overcome harsh conditions, such as salty air or areas needing repetitive cleaning, with durable 303 materials and a design with proven success. Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-108-860MSP VALVE, ASSY MSP-20S-SS
GG 562756
MSP VALVE, ASSY MSP-20S-SS
Trabon® MSP Stainless Steel Modular Divider Valve - MSP-20S-SS - 0.040 in³ (0.66 cm³) The Trabon MSP Stainless Steel Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best! You get more durability with the same high-quality performance and precision machining as the carbon steel version. The stainless steel MSP valves and accessories overcome harsh conditions, such as salty air or areas needing repetitive cleaning, with durable 303 materials and a design with proven success. Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-108-880MSP VALVE, ASSY MSP-40S-SS
GG 562757
MSP VALVE, ASSY MSP-40S-SS
Trabon® MSP Stainless Steel Modular Divider Valve - MSP-40S-SS - 0.080 in³ (1.31 cm³) The Trabon MSP Stainless Steel Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best! You get more durability with the same high-quality performance and precision machining as the carbon steel version. The stainless steel MSP valves and accessories overcome harsh conditions, such as salty air or areas needing repetitive cleaning, with durable 303 materials and a design with proven success. Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-108-920MSP VALVE, ASSY MSP-10T-SS
GG 562758
MSP VALVE, ASSY MSP-10T-SS
Trabon® MSP Stainless Steel Modular Divider Valve - MSP-10T-SS - 0.010 in³ (0.16 cm³) The Trabon MSP Stainless Steel Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best! You get more durability with the same high-quality performance and precision machining as the carbon steel version. The stainless steel MSP valves and accessories overcome harsh conditions, such as salty air or areas needing repetitive cleaning, with durable 303 materials and a design with proven success. Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-108-940MSP VALVE, ASSY MSP-20T-SS
GG 562759
MSP VALVE, ASSY MSP-20T-SS
Trabon® MSP Stainless Steel Modular Divider Valve - MSP-20T-SS - 0.020 in³ (0.33 cm³) The Trabon MSP Stainless Steel Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best! You get more durability with the same high-quality performance and precision machining as the carbon steel version. The stainless steel MSP valves and accessories overcome harsh conditions, such as salty air or areas needing repetitive cleaning, with durable 303 materials and a design with proven success. Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-108-960MSP VALVE, ASSY MSP-40T-SS
GG 562760
MSP VALVE, ASSY MSP-40T-SS
Trabon® MSP Stainless Steel Modular Divider Valve - MSP-40T-SS - 0.040 in³ (0.66 cm³) The Trabon MSP Stainless Steel Series sets the industry standard for quality, reliability, and ease of use features. It was the original modular-style series progressive divider valve and is still the best! You get more durability with the same high-quality performance and precision machining as the carbon steel version. The stainless steel MSP valves and accessories overcome harsh conditions, such as salty air or areas needing repetitive cleaning, with durable 303 materials and a design with proven success. Quick change valve sections can be removed from the base assembly without disturbing any lube lines - minimizing labor cost and maximizing your machine uptime Accessories such as magnetic and electronic proximity switch cycle indicators provide positive assurance of a successful lube event. Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Built-in outlet check valves ensure accurate lube delivery every time Lubriquip part number 106-109-000MXP VALVE, TWIN 50T
GG 562814
MXP VALVE, TWIN 50T
Trabon® MXP Modular Divider Valve - MXP-50T - 0.050 in³ (0.82 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-020VAVLE, TWIN MXP-75T
GG 562815
VAVLE, TWIN MXP-75T
Trabon® MXP Modular Divider Valve - MXP-75T - 0.075 in³ (1.23 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-030MXP VALVE, TWIN 125T
GG 562817
MXP VALVE, TWIN 125T
Trabon® MXP Modular Divider Valve - MXP-125T - 0.125 in³ (2.05 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-050MXP VALVE, TWIN 150T
GG 562818
MXP VALVE, TWIN 150T
Trabon® MXP Modular Divider Valve - MXP-150T - 0.150 in³ (2.46 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-060MXP VALVE, SINGLE 25S
GG 562819
MXP VALVE, SINGLE 25S
Trabon® MXP Modular Divider Valve - MXP-25S - 0.050 in³ (0.82 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-070MXP VALVE, SINGLE 75S
GG 562821
MXP VALVE, SINGLE 75S
Trabon® MXP Modular Divider Valve - MXP-75S - 0.150 in³ (2.46 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-090MXP VALVE, TWIN 100T W/IND
GG 562827
MXP VALVE, TWIN 100T W/IND
Trabon® MXP Modular Divider Valve with Indicator - MXP-100T - 0.100 in³ (1.64 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-150MXP VALVE, TWIN 75T W/IND
GG 562826
MXP VALVE, TWIN 75T W/IND
Trabon® MXP Modular Divider Valve with Indicator - MXP-75T - 0.075 in³ (1.23 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-140MXP VALVE, SINGLE 125S
GG 562823
MXP VALVE, SINGLE 125S
Trabon® MXP Modular Divider Valve - MXP-125S - 0.250 in³ (4.10 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-110MXP VALVE, TWIN 50T W/IND
GG 562825
MXP VALVE, TWIN 50T W/IND
Trabon® MXP Modular Divider Valve with Indicator - MXP-50T - 0.050 in³ (0.82 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-130MXP VALVE, TWIN 150T W/IND
GG 562829
MXP VALVE, TWIN 150T W/IND
Trabon® MXP Modular Divider Valve with Indicator - MXP-150T - 0.150 in³ (2.46 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-170MXP VALVE, TWIN 125T W/IND
GG 562828
MXP VALVE, TWIN 125T W/IND
Trabon® MXP Modular Divider Valve with Indicator - MXP-125T - 0.125 in³ (2.05 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-160MXP VALVE, SINGLE 50S W/IND
GG 562830
MXP VALVE, SINGLE 50S W/IND
Trabon® MXP Modular Divider Valve with Indicator - MXP-50S - 0.100 in³ (1.64 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-180MXP VALVE, SINGLE 75S W/IND
GG 562831
MXP VALVE, SINGLE 75S W/IND
Trabon® MXP Modular Divider Valve with Indicator - MXP-75S - 0.150 in³ (2.46 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-190MXP VALVE, SINGLE 100S W/IND
GG 562832
MXP VALVE, SINGLE 100S W/IND
Trabon® MXP Modular Divider Valve with Indicator - MXP-100S - 0.200 in³ (3.28 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-200MXP VALVE, SINGLE 125S W/IND
GG 562833
MXP VALVE, SINGLE 125S W/IND
Trabon® MXP Modular Divider Valve with Indicator - MXP-125S - 0.250 in³ (4.10 cm³)The Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-210MXP VALVE, BYPASS
GG 562835
MXP VALVE, BYPASS
Trabon® MXP Divider Valve - MXP BypassThe Trabon MXP Series offers the largest output available in a series progressive system. Can be easily accessorized with magnetic and electronic proximity switch cycle indicators to provide positive assurance of a successful lube event.
Ideal for heavy-duty and large bearing applications with wide temperature variations and high volume requirements. Quick change valve sections can be removed from the base assembly without disturbing any lube lines–minimizing labor cost and maximizing your machine uptime Alternate outlet on face of valves can be fitted with optional performance indicators, taking the guesswork out of troubleshooting Robust design is virtually indestructible and built to perform in extreme environments Lubriquip part number 106-300-410Injecto-Flo Pump, Eo-3 W/O Timer Llvl Nc
GG 562852
Injecto-Flo Pump, Eo-3 W/O Timer Llvl NcRESERVOIR, PLSTC OIL LUBEMASTER 12P
GG 562892
RESERVOIR, PLSTC OIL LUBEMASTER 12P
12 pt. Plastic Oil Reservoir For use with LubriSystem and Lube Master Pumps.12 pt Plastic Oil Reservoir
Lubriquip part number 185-100-380RESERVOIR, PLASIC OIL LUBEMASTER 20
GG 562893
RESERVOIR, PLASIC OIL LUBEMASTER 20
20 pt. Plastic Oil Reservoir For use with LubriSystem and Lube Master Pumps.20 pt (9.46 liter) Oil Reservoir
Lubriquip part number 185-100-390RESERVOIR, MTL OIL LUBEMASTER 20PT
GG 562895
RESERVOIR, MTL OIL LUBEMASTER 20PT
20 pt. Metal Oil Reservoir For use with Lube Master Pumps.20 pt Metal Oil Reservoir
Lubriquip part number 185-100-410RESERVOIR, PLSTC GRS LUBEMASTER 12L
GG 562896
RESERVOIR, PLSTC GRS LUBEMASTER 12L
12 lb. Plastic Grease Reservoir For use with LubriSystem and Lube Master Pumps.12 lb (5.44 kg) Reservoir
Lubriquip part number 185-100-540RESERVOIR, LUBEMASTER, GREASE, 20LB, METAL
GG 562899
RESERVOIR, LUBEMASTER, GREASE, 20LB, METAL
20 lb. Metal Grease Reservoir For use with Lube Master Pumps.20 lb metal grease reservoir
Lubriquip part number 185-100-570RESERVOIR, LUBEMASTER, GREASE, 12LB, METAL
GG 562898
RESERVOIR, LUBEMASTER, GREASE, 12LB, METAL
12 lb. Metal Grease Reservoir For use with Lube Master Pumps.12 lb metal grease reservoir
Lubriquip part number 185-100-560TUBE, RESV REPLACE PLSTC 5LB
GG 562901
TUBE, RESV REPLACE PLSTC 5LB
Modu-Flo and E-Pump Spare Parts and Accessories - 5 pt./lb. Plastic Replacement Reservoir Assembly, 4 in OD x 13 in long For use with Modu-Flo and E-Series Pneumatic Pumps.5 pt/lb plastic replacement reservoir assembly (4 in O.D. x 13 in long)
Lubriquip part number 185-100-720RESERVOIR, 6LB GRS PLSTC
GG 562907
RESERVOIR, 6LB GRS PLSTC
6 lb. Plastic Grease Reservoir For use with LubriSystem Pumps.6 lb (2.72 kg) Reservoir
Lubriquip part number 185-100-780RESERVOIR, ASSY POWER PRIME
GG 562908
RESERVOIR, ASSY POWER PRIME
Power Prime/Overhead Supply Reservoir Assembly For use with Lube Master Pumps.Power Prime Reservoir Assembly
Lubriquip part number 185-100-930BAR, CROSSPORT MJ
GG 562914
BAR, CROSSPORT MJ
Trabon® MJ Divider Valve Accessories - Cross Port Bar For use with Trabon® MJ Divider Valves. Cross Port Bar Lubriquip part number 189-000-040BAR, CROSSPORT MX
GG 562917
BAR, CROSSPORT MX
Trabon® MX Divider Valve Accessories - Cross Port Bar For use with Trabon® MX Divider Valves. MX cross port bar, RH or LH Lubriquip part number 189-000-090 Trabon part number 10965HP-50 LUBRICATOR
GG 562925
HP-50 LUBRICATOR
HP-50 Lubricator with 4 PumpsSingle plunger force feed design is highly efficient for injecting lubricants and/or compatible fluids into high pressure systems. Vacuum sight feeds on self-contained pumping units show output of lubricant to individual lubrication points.
For lubricating compressor and circulator cylinder walls, heavily loaded bearings and other moving parts. Operating pressures up to 60,000 psi (4137 bar) All working parts are totally enclosed and self-lubricated Individual pumping units easily removed for service Feed rate infinitely variable from minimum to maximum with simple hand adjustment Lubriquip part number 250-000-269