GG 26A814
GLC CONTROL, X
Graco 26A814 GLC X Controller
The powerful, new, easy-to-use Graco GLC X auto lubrication controller captures more information more ways, so operators, technicians and managers can make faster, smarter decisions that drive more productivity.
- Indoor/Outdoor Mountable (IP69K) - Designed to withstand all the elements, including high-pressure washes and inclement weather encountered at the harshest and dirtiest sites.
- Easy-to-Read LED Screen - Soft amber LED lighting capable of displaying text codes, faults and other data clearly in any ambient light without distracting operators.
- Real-Time System Reporting - Program and display a wide range of customizable functions - including lubrication intervals, pressure limits, lubricant levels and more.
- Universal Compatibility - One controller for all your lubrication systems simplifies training and inventory.
- Active Current Protection - 9-30 VDC, 10 Amp continuous power supply protects grease pumps from over current and entire system from misfires, electrical shorts and surges.
- Amperage (A): 15
- Application: In-Plant Machinery, Off-Road Equipment, On-Road Vehicles
- Auxiliary Alarm Max Switching Current (A): 10
- Auxiliary Alarm Max Switching Voltage (VDC): 9-30
- Auxiliary Alarm Voltage: 9-30 VDC
- Control Mode: Timer, Pressure, Cycle
- Count Rate (counts/sec @ 50% duty cycle): 5
- Current Consumption (A): 15
- Low Level Alarm Max Switching Current (A): 10
- Low Level Alarm Max Switching Voltage (VDC): 30
- Lubrication Level Input: Input 1: 10V
- Machine Count Control Input: Input 4
- Maximum Operating Temperature ( degree C): 70
- Maximum Operating Temperature ( degree F): 158
- Maximum Program Time (min): 99
- Maximum Program Time (sec): 5999
- Maximum Storage Temperature ( degree C): 70
- Maximum Storage Temperature ( degree F): 158
- Maximum System Cycle Count: 100
- Maximum Voltage (V dc): 30
- Maximum Voltage (V): 30
- Minimum Ambient Temperature ( degree F): -22
- Minimum Monitor Time (hrs): 0
- Minimum Monitor Time (min): 1
- Minimum Monitor Time (sec): 0
- Minimum Monitor Time (strokes): 1
- Minimum Operating Temperature ( degree C): -30
- Minimum Operating Temperature ( degree F): -22
- Minimum Program Time (hrs): 0
- Minimum Program Time (min): 0
- Minimum Program Time (sec): 10
- Minimum Program Time (strokes): 1
- Minimum Storage Temperature ( degree C): -30
- Minimum Storage Temperature ( degree F): -22
- Minimum System Cycle Count: 1
- Minimum Voltage (V dc): 9
- Minimum Voltage (V): 9
- Overall Depth (cm): 5
- Overall Depth (in): 1.98
- Overall Height (cm): 16.9
- Overall Height (in): 6.66
- Overall Height (mm): 169
- Overall Width (cm): 9.2
- Overall Width (in): 3.62
- Overall Width (mm): 92
- Power Consumption (W): 450
- Pump Control Max Switching Current (A): 10
- Pump Control Max Switching Voltage (VDC): 30
- Pump Control Voltage (VDC): 9-30